Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"3.6\/6kV 6\/10kV XLPE Flame Retardant Cable NH-YJV For Emergency Feeders","imgUrl":"https:\/\/img.ismap.com\/nimg\/5a\/c0\/5fee2729209c4013a5d377cfeb34-200x200-1\/3_6_2f6kv_6_2f10kv_xlpe_flame_retardant_cable_nh_yjv_for_emergency_feeders.jpg","attrs":{"Brand Name":"JinHong","Model Number":"NH-YJV","Place of Origin":"Anhui China","Minimum Order Quantity":"100m"}}
{"title":"NH-KVV Fire Rated Control Cable For Critical LV Control Circuits","imgUrl":"https:\/\/img.ismap.com\/nimg\/72\/52\/90c57b1d447e9091ce8ac4f054d1-200x200-1\/nh_kvv_fire_rated_control_cable_for_critical_lv_control_circuits.jpg","attrs":{"Brand Name":"JinHong","Model Number":"NH-KVV","Place of Origin":"Anhui China","Minimum Order Quantity":"100m"}}
{"title":"Emergency Command Circuits Fire Rated Wire NH-KVV Multi Core Control Cable","imgUrl":"https:\/\/img.ismap.com\/nimg\/b2\/76\/e3ffe980430d67c121978f292f12-200x200-1\/emergency_command_circuits_fire_rated_wire_nh_kvv_multi_core_control_cable.jpg","attrs":{"Brand Name":"JinHong","Model Number":"NH-KVV","Place of Origin":"Anhui China","Minimum Order Quantity":"100m"}}
{"title":"1.5mm2 To 400mm2 Fire Resistant Cable NH-VV PVC power Cable 0.6\/1kV","imgUrl":"https:\/\/img.ismap.com\/nimg\/56\/df\/bbcc19aa4bce7e6f7ffc7941cf13-200x200-1\/1_5mm2_to_400mm2_fire_resistant_cable_nh_vv_pvc_power_cable_0_6_2f1kv.jpg","attrs":{"Brand Name":"JinHong","Model Number":"NH-VV","Place of Origin":"Anhui China","Minimum Order Quantity":"100m"}}
{"title":"XLPE Copper Fire Rated Cable 500V NH-YJV 4 Cores 5 Cores Fire Proof Cable","imgUrl":"https:\/\/img.ismap.com\/nimg\/b0\/f5\/78775a89729bdaea5be602dbd38c-200x200-1\/xlpe_copper_fire_rated_cable_500v_nh_yjv_4_cores_5_cores_fire_proof_cable.jpg","attrs":{"Brand Name":"JinHong","Model Number":"NH-YJV","Place of Origin":"Anhui China","Minimum Order Quantity":"100m"}}
{"title":"ZR-YJV Fire Retardant Cable 0.6\/1kV To 33kV Heat Resistant Cables","imgUrl":"https:\/\/img.ismap.com\/nimg\/ff\/4f\/a430bf1535cc26277896c6003d90-200x200-1\/zr_yjv_fire_retardant_cable_0_6_2f1kv_to_33kv_heat_resistant_cables.jpg","attrs":{"Brand Name":"JinHong","Model Number":"ZR-YJV","Place of Origin":"Anhui China","Minimum Order Quantity":"100m"}}
{"title":"ZR-YJV22 XLPE Armored Cable 12\/20kV Fire Resistant Cable For Underground","imgUrl":"https:\/\/img.ismap.com\/nimg\/aa\/49\/c7220ba31bb1e88ce8a18eaecc58-200x200-1\/zr_yjv22_xlpe_armored_cable_12_2f20kv_fire_resistant_cable_for_underground.jpg","attrs":{"Brand Name":"JinHong","Model Number":"ZR-YJV22","Place of Origin":"Anhui China","Minimum Order Quantity":"100m"}}
NH-YJV Fire Resistant XLPE Power Cable 0.6/1kV for Emergency Feeders
NH-YJV is a fire-resistant low-voltage cross-linked polyethylene (XLPE) power cable designed to maintain circuit integrity and operate continuously for a period of time during fire exposure, in accordance with applicable standards. It is typically used in emergency and life-safety power circuits to ensure power continuity for evacuation and firefighting operations. NH-YJV features copper conductors, XLPE insulation, and integrated fire-resistant elements in its construction, making it suitable for critical feeders powering emergency lighting, fire pumps, smoke exhaust fans, booster systems, and important switchboards.
For cross-border sourcing, NH-YJV is an ideal choice for projects requiring fire-resistant XLPE insulated power cables, offering compliance, superior performance, and ease of installation in building and infrastructure wiring.
Rated Voltage
Typical rated voltage: 0.6/1 kV
Please confirm the required rated voltage, fire resistance rating, and duration in your Bill of Quantities (BOQ) and project standards.
Application Areas of NH-YJV
Typical Emergency and Critical Power Applications
Emergency lighting main and branch feeders
Fire pump power circuits
Smoke exhaust and booster fan feeders
Emergency ventilation and critical HVAC power supplies
Critical switchboards and life safety switchboards
Critical loads in tunnels, stations, airports, and high-rise buildings (depending on the project)
Typical Installation Routes
Fixed installation in cable trays, conduits, cable trays, risers, shafts, equipment rooms, and protected indoor routes. For routes with high mechanical loads, please specify whether armoring is required.
General Specifications Overview
Common Core Wire Configurations
1C for high-current feeders and phase-separated wiring
2C for dedicated single-phase emergency loads
3C for three-phase without neutral (project-specific)
4C for three-phase with neutral (common)
5C for three-phase with neutral and PE (common)
3+1 and 3+2 for feeder designs common in many markets (project-specific)
Common Cross-Section Sizes (mm²)
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
High-Frequency Emergency Project Combinations
4C x 10
4C x 16
4C x 25
4C x 35
5C x 10
5C x 16
5C x 25
3C x 10
3C x 16
3C x 25
1C x 95
1C x 120
1C x 150
1C x 185
2C x 4
2C x 6, suitable for single-phase emergency lines
Availability depends on conductor grade and fire-resistant construction requirements of relevant standards.
Reasons buyers choose NH-YJV:
Fire-resistant continuity, ensuring life safety
Designed to keep emergency power circuits operational for a period of time during a fire, supporting evacuation systems and fire-fighting equipment.
XLPE insulation, superior thermal performance
XLPE insulation core material has stable dielectric and thermal properties, making NH-YJV suitable for emergency feeders with continuous load requirements.
Compliance Requirements for Public and Enclosed Facilities
Commonly used in hospitals, shopping malls, high-rise buildings, stations, and infrastructure projects where emergency feeders must remain operational in the event of a fire.
Efficient EPC Procurement and Repeatable Bills of Quantities
Universal feeder sizes and repeatable construction support standardized procurement and phased delivery.
Easy Installation and Termination
The YJV type construction supports easy termination and routing planning in typical building power distribution environments.
Manufacturing and Process Specifications
Copper Conductor Preparation
Copper is drawn and stranded to meet resistance requirements and installation flexibility objectives.
Fire-Resistant Component Integration
Special fire-resistant layers are applied according to required standards to ensure circuit integrity in a fire.
XLPE Insulation Extrusion and Crosslinking
XLPE insulation is extruded and crosslinked to form a robust dielectric layer suitable for low-voltage feeders.
Cable and Core Assembly
For multi-core designs, insulated cores are stranded with a controlled pitch; fillers and adhesives can be used to stabilize the geometry.
Sheath Extrusion and Finishing
An outer sheath is applied to provide mechanical protection and improve installation durability, followed by marking and packaging controls for project delivery.
Routine Testing and Compliance Checks
Typical checks include conductor resistance, insulation thickness control, spark testing, voltage testing, dimensional verification, and continuity checks. Fire resistance verification is performed according to the required rating.
Structural Overview
Conductor:
Copper
Fire Resistance:
Fire-resistant layer (as per standard design)
Insulation:
Cross-linked polyethylene (XLPE)
Outer Sheath:
Polyvinyl chloride (PVC) or specified sheath system (depending on tender requirements)
Applications:
Fire-resistant low-voltage power feeders and emergency distribution circuits
Specifications
Model:
NH-YJV
Cable Category:
Fire-resistant cross-linked polyethylene (XLPE) power cable
Rated Voltage:
0.6/1 kV
Conductor:
Copper stranded wire (as per standard classification)
Fire Resistance:
As required standard and duration
Insulation:
Cross-linked polyethylene (XLPE)
Sheath:
As specified in the standard or Bill of Quantities (BOQ) (often PVC))
Core Options:
Single core, double core, triple core, four cores, five cores, three-core single core, three-core double core
When a project requires fire-resistant low-voltage cross-linked polyethylene (XLPE) power cables to ensure the emergency feeder operates normally during a fire, select NH-YJV.
Confirm the fire resistance duration and reference standards to avoid incorrect replacement.
Select the number of cores based on system design and neutral/PE resistance requirements.
Select the cross-sectional area based on load current, line length, ambient temperature, grouping, and allowable voltage drop.
If the line is underground or has high mechanical requirements, specify whether armored fire-resistant cables are required.
NH-YJV is used for emergency low-voltage feeders that must remain operational during a fire, such as emergency lighting, fire pumps, and smoke extraction systems. Specific applications must comply with project standards.
What does NH usually represent?
NH usually indicates fire-resistant construction, designed to maintain circuit integrity during a fire. Specific testing methods and durations are specified by relevant standards.
How does NH-YJV differ from standard YJV?
NH-YJV includes a fire-resistant element designed to maintain circuit integrity in fire conditions, while standard YJV does not.
Is NH-YJV suitable for high-current feeders?
Yes. It is typically used for emergency feeders. The final size selection should be based on load current, line length, grouping method, and permissible voltage drop.
Does NH-YJV always use a PVC sheath?
The sheath type depends on standards and tender requirements. Many projects use PVC sheaths, while some specify the use of low-smoke halogen-free systems. Please follow the requirements of the Bill of Quantities (BOQ).
What information is needed for an accurate quote?
Fire resistance requirements and duration, rated voltage, core configuration, cross-section, total length, required standards, packaging preferences, and destination.
Service of JinHong Company
Over Productions Service:
JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.
Quality Certification Services:
JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.
Profession Customer Service:
JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.
Delivery And Shipping Services:
While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.
Packaging of JinHong:
JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.