China factories

China factory - Shanghai Orsin Medical Technology Co., Ltd.

Shanghai Orsin Medical Technology Co., Ltd.

  • China,Shanghai ,Shanghai
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China 2ml ESR Blood Collection Tube with Sodium Citrate Anticoagulant
China 2ml ESR Blood Collection Tube with Sodium Citrate Anticoagulant

  1. China 2ml ESR Blood Collection Tube with Sodium Citrate Anticoagulant

2ml ESR Blood Collection Tube with Sodium Citrate Anticoagulant

  1. MOQ: 100/pcs
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union
Supply Ability 20million/pcs/moth
Delivery Time 1-4 weeks
Application Scenarios Room-Temperature Storage
Anticoagulant System Composite Antimony System Technology
Behavior Strong temperature tolerance
Productivity 12000pcs/hour
Inner Wall Treatment Bionic active membrane
Color black
Material Glass or pet
milliliter 2
Standardized Anticoagulant yes
Brand Name Orsin
Model Number Gel Clot ActivatoR
Certification ISO 13485
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union Supply Ability 20million/pcs/moth
Delivery Time 1-4 weeks Application Scenarios Room-Temperature Storage
Anticoagulant System Composite Antimony System Technology Behavior Strong temperature tolerance
Productivity 12000pcs/hour Inner Wall Treatment Bionic active membrane
Color black Material Glass or pet
milliliter 2 Standardized Anticoagulant yes
Brand Name Orsin Model Number Gel Clot ActivatoR
Certification ISO 13485 Place of Origin China
High Light 2ml sodium citrate blood tubeESR blood collection tubevacuum blood test tube with anticoagulant

Orsin Medical Technology ESR Blood Collection Tubes

Orsin Medical Technology's ESR Blood Collection Tubes are designed for precise and efficient erythrocyte sedimentation rate (ESR) testing in clinical settings. These tubes ensure reliable results through strict adherence to international standards and advanced manufacturing processes.

 Product Highlights: Technological Innovation Ensures Accuracy

ESR tubes incorporate advanced engineering to deliver superior clinical performance:

Scenario Type Application Description Target Users Key Benefits
Clinical Diagnostics Routine ESR testing for inflammation monitoring in hospitals and clinics. Pathologists, Lab Technicians Standardized anticoagulant ensures accurate results for diagnostic consistency.
Autoimmune Disease Management Tracking disease activity in conditions like rheumatoid arthritis or lupus. Rheumatologists, Immunologists Reliable ESR data supports treatment adjustment and progression monitoring.
Infection Monitoring Assessing inflammatory responses in bacterial infections, sepsis, or postoperative care. Infectious Disease Specialists, Surgeons Rapid and precise ESR measurement aids in infection control and recovery assessment.
Research Studies Academic or clinical research involving inflammatory biomarkers. Researchers, Biotechnologists High sample clarity and compliance with international standards support data validity.
Primary Care Screening Initial inflammation screening in community healthcare settings. General Practitioners, Nurses Easy identification (black cap) reduces sampling errors and improves workflow efficiency.
Pediatric & Geriatric Care ESR testing for age-specific inflammatory conditions (e.g., childhood infections or aging-related diseases). Pediatricians, Geriatricians Gentle vacuum design and safety-certified materials minimize patient discomfort.
   

Usage Precautions: Standardized Operations Ensure Reliability

3.1 Pre-collection Preparation

  • Tube Selection: Verify black-capped ESR-specific tubes contain 3.8% sodium citrate. Inspect for particulates, sedimentation, or cap looseness.

  • Storage Conditions: Store at 4-25°C. Avoid freezing (causes tube fracture) or high temperatures (degrades anticoagulant).

  • Patient Preparation: Collect blood from calm, preferably fasting patients. Note non-fasting status on requisition forms.

3.2 Blood Collection Protocol

  • Order of Draw: Follow international sequence: blood culture → coagulation tubes → other anticoagulant tubes → ESR tubes (black cap). Prevents anticoagulant cross-contamination.

  • Exact Fill Volume: Draw precisely to fill line (typically 2mL). Underfilling causes false-low ESR; overfilling promotes microclot formation.

  • Mixing Technique: Gently invert 5-10 times immediately after collection. Avoid vigorous shaking to prevent partial anticoagulation or hemolysis.

3.3 Post-collection Handling

  • Testing Timeline: Analyze within 2 hours. Delayed testing alters erythrocyte morphology. Store at 18-25°C if necessary (NEVER refrigerate).

  • Tube Orientation: Transport upright to avoid disturbing sedimentation.

  • Sample Rejection Criteria: Reject clotted, severely hemolyzed, improperly filled (>±10%), unlabeled, or damaged specimens.

*Note: 30% of ESR errors originate from pre-analytical issues, primarily inaccurate fill volumes and improper mixing.*

 Technical Specifications: Standard-Compliant Parameters

 
arameter Category Specification Detail
Intended Use For the collection of venous blood and the measurement of Erythrocyte Sedimentation Rate (ESR).
Anticoagulant Tri-Sodium Citrate (Na<sub>3</sub>C<sub>6</sub>H<sub>5</sub>O<sub>7</sub> · 2H<sub>2</sub>O)
Concentration 3.2% (0.109 Molar) or 3.8% (Note: 3.2% is the ICSH international standard)
Blood to Additive Ratio 4:1 (e.g., 1.6 mL draw volume with 0.4 mL citrate)
Tube Size Common sizes: 13x75 mm, 16x100 mm
Draw Volume Common volumes: 1.8 mL, 2.4 mL, 2.7 mL, 4.5 mL
Tube Material Clear PET (Polyethylene Terephthalate) or Glass
Closure Color Black (ISO 6710 & CLSI Standard)
Sterility Sterilized by Radiation (SAL 10<sup>-6</sup>)
Endotoxin Level ≤ 0.5 EU/mL (As per USP/EP standards)
Shelf Life Typically 12-24 months from date of manufacture.

 

Key Features:

  • Anticoagulant Formula: Pre-filled with 3.2% sodium citrate (ICSH-compliant) to maintain optimal blood-to-anticoagulant ratio (4:1).

  • Distinct Design: Black cap for instant recognition and reduced risk of sampling errors (per ISO 6710).

  • Material Excellence: Crafted from high-quality PET or glass to ensure sample integrity and clarity.

  • Rigorous Quality Control: Sterilized, endotoxin-tested (<0.5 EU/mL), and validated for performance (CLSI H21-A5).

  • Automation Compatibility: Seamlessly integrates with automated ESR analyzers for streamlined processing.

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Trading Company,Seller

  • Year Established:

    2010

  • Employee Number:

    30~60

  • Ecer Certification:

    Verified Supplier

Shanghai Orsin Medical Technology Co., Ltd. is located in No. 599, Wanhua Road, Zhelin Town, Fengxian District, Shanghai. Is China's production of one-time vacuum collection of professional companies, Shanghai Medical Device Industry Backbone Enterprises. The product takes Orsin pattern as the r... Shanghai Orsin Medical Technology Co., Ltd. is located in No. 599, Wanhua Road, Zhelin Town, Fengxian District, Shanghai. Is China's production of one-time vacuum collection of professional companies, Shanghai Medical Device Industry Backbone Enterprises. The product takes Orsin pattern as the r...

+ Read More

Get in touch with us

  • Reach Us
  • Shanghai Orsin Medical Technology Co., Ltd.
  • Building A, No.599 Wanhua Road, Zhelin Town, Fengxian Area, Shanghai, China
  • https://www.blood-tubes.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement