Payment Terms | T/T |
Supply Ability | 10 pieces a day |
Delivery Time | today |
Packaging Details | new and original with factory sealed |
Manufacture Year | 2016 |
Control System | ABB Module System |
Application | Nuclear Power Plant |
lead time | in stock |
description | DO620 3BHT300009R1 ABB DO620 DIGITAL OUPUT USED |
Weight | 4lbs |
Brand Name | ABB Module |
Model Number | DO620 |
Certification | CO.CQ |
Place of Origin | Sweden |
View Detail Information
Explore similar products
ABB Module 3ASU21C110 LU6278 DCU30/7 ABB 3ASU21C110 DESK CONTROL UNIT Performanc
ABB CI855K01 3BSE018106R1 MB 300 Dual Ethernet Port Interface Kit
*Complete in specifications* ABB KSML92S1450-W-MC1 IEC60945 Industrial keyboard
ABB Module 07NG63R1 GJV3074313R1 Textile Printing Machinery Power Supply
Product Specification
Payment Terms | T/T | Supply Ability | 10 pieces a day |
Delivery Time | today | Packaging Details | new and original with factory sealed |
Manufacture Year | 2016 | Control System | ABB Module System |
Application | Nuclear Power Plant | lead time | in stock |
description | DO620 3BHT300009R1 ABB DO620 DIGITAL OUPUT USED | Weight | 4lbs |
Brand Name | ABB Module | Model Number | DO620 |
Certification | CO.CQ | Place of Origin | Sweden |
High Light | abb plc , advant controller 31 |
ABB Module DO620 3BHT300009R1 ABB DO620 DIGITAL OUPUT USED Performance great
Product Description:
In case of a configured plausibility monitoring, range underflow and range overflow by 2...3 % result in an error message (FK4, error number 10).Independent of the configured monitoring, the error values +32767 and -32767 are always generated in case of range underflow and range overflow. Exception: In the measuring range of 0...20 mA only the range overflow is detected.Input voltages that exceed the measuring range cause the overflow numerical value of +32767. If the measuredvalue is below the range, the underflow numerical value of -32767 is set.Input currents that exceed the measuring range caus the overflow numerical value of +32767. If the measured value is below the range, the underflow numerical value of -32767 is set.The input impedance is ca. 330 Ω. The current input hasa self-protecting mechanism. If the input current gets too high, the shunt is switched off and the value for range overflow is generated. About every second, the unit tries to switch on the shunt again. In this way the correct measurement.
Related Product Recommendation:
PCU-03 | MM21 MM 21 | ECZ FPR3700001R0001 |
PE1364B | MPRC 086349-002 | EL3020 |
PHARPS32200000 | MV03 MV 03 | GJR2370500R2 |
PHARPS62200000 | MZ03 MZ 03 | GJV3072403R1 07KR264DR1 07KR264B |
PHARPSPEP11013 | NAIO-01 | GJV3074353R1 07EA63R1 |
PM150V08 3BSE003641R1 | NAOM01 | HS01 HS 01 |
PM253V01 | NGDR-02C | ICMK14N1 1SBP260052R1001 |
PM510 3BSE000270R1 | NISA-03 | ICSA04B5 FPR3341501R1042 |
PM511V08 3BSE011180R1 | NTAC-02 | ICSE08B5 FPR3346501R1012 |
PM630 3BSE000434R1 | NTAI05 | IDS-DTU51 |
PM632 3BSE005831R1 | NTAI06 | IMASI03 |
PM633 3BSE008062R1 | NTCL01 | IMASI23 |
PM645C 3BSE010537R1 | NTCL01-A | IMASO11 |
PM810V2 3BSE013220R1 | NTCS04 | 07SK90R1 |
PM860K01 3BSE018100R1 | NTDI0-A | 07ZE63R302 |
SAFT132CBS SAFT 132 CBS | NTDI01 | DSAI145 |
SAFT132CBS SAFT 132 CBS 57411619 | NTRO02 NTRO02-A | DSBC173 57310001-KH |
SAFT185TBC SAFT 185 TBC 58119687 | DSQC205 YB560103-BK | DSCS140 |
SAFT187CON | XM06B5 1SBP260103R1001 | IDS-DTU51 57520001-EV |
SAFT190APC SAFT 190 APC | XN03 XN 03 | DSDX451L |
DSTC454 5751017-F 57160001-ABD/ABW | XN05 XN 05 | DSDP170 DSDP 170 57160001-ADF 5716075-AH |
DSTC190 57520001-ER 57160001-TZ | XN06 XN 06 | DSDX451L 5716075-AH |
DSTA180 | XO08R1 XOO8R1-B04 1SBP260101R1001 | 07SK90R1 GJR5250200R0001 |
DSTA160 | DDO01 | IMFCS01 |
CI540 3BSE001077R1 | DI685 3BDS005833R1 | IMFEC12 |
CI570 3BSE001440R1 | DI811 3BSE008552R1 | IMMPI01 |
CI590 3BHT340092R1 | DIGITRIC 500 61615-0-1200000 | IMRIO02 |
Product's Character:
The trigger of the self-protecting mechanism is displayed by the red LED Ovl as long as the overload is present. In the PLC system an error message is then stored (FK4, error number 4).The open-circuit monitoring begins below ca. 3 mA. The value of the range underflow is stored. If the open-circuit
monitoring is configured, the open-circuit event is displayed by the red LED Ovl as long as it is present. In the PLC system an error message is stored (FK4, error number 9).The following figure shows the connection of 2-pole passive.type analog sensors 4...20 mA.
The use of the product:
1.Avoid unplanned downtime
2.Experienced technichal support team.
3.365 days warranty for all the goods from us.
1. Q: Do you provide warranty for the goods?
A: Yes, we provide warranty for all the goods from us.
2.Q: Can you provide discount ?
A: Yes, we are glad to offer you dicount if you order more than 1 piece .
3. Q: Does Moore keeps goods in stock or only trading?
A: We have large warehouse for goods. Keep lots of goods in warehouse, so could promise fast delivery.
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )
Company Details
Business Type:
Agent,Trading Company
Year Established:
2011
Total Annual:
<200000000
Employee Number:
80~100
Ecer Certification:
Verified Supplier
Moore Automation is a company specializing in the sales of modules and spare parts for world-renowned brands (DCs systems, robot systems, large servo control systems). The company's products include: distributed control systems (DCS), programmable controllers (PLC), MOTOROLA -MVME industrial mod... Moore Automation is a company specializing in the sales of modules and spare parts for world-renowned brands (DCs systems, robot systems, large servo control systems). The company's products include: distributed control systems (DCS), programmable controllers (PLC), MOTOROLA -MVME industrial mod...
Get in touch with us
Leave a Message, we will call you back quickly!