Payment Terms | T/T, Alipay, Paypal |
Supply Ability | 1000pcs per week |
Delivery Time | Negotiable |
Packaging Details | carton |
Product No. | MTL5516C |
Product type | Switch/Proximity Detector Interface |
Barrier Type | Galvanic |
Number of Channels | 2 |
Safety Voltage Maximum | 10.5 V |
Safety Current Maximum | 14mA |
Signal Type | NAMUR Input, Relay Output |
Shipping weight | 1 Kg |
Brand Name | MTL |
Model Number | MTL5516C |
Certification | HART |
Place of Origin | UK/China |
View Detail Information
Explore similar products
MTL5561 MTL Instruments MTL Fire & Smoke Detector Interface
MTL5576-RTD MTL Instruments | 2ch Temperature converter, RTD
MTL5576-THC MTL Instruments Temperature Converter Number Of Channels Two
MTL5522 MTL Instruments Solenoid / Alarm Driver Number of channels One
Product Specification
Payment Terms | T/T, Alipay, Paypal | Supply Ability | 1000pcs per week |
Delivery Time | Negotiable | Packaging Details | carton |
Product No. | MTL5516C | Product type | Switch/Proximity Detector Interface |
Barrier Type | Galvanic | Number of Channels | 2 |
Safety Voltage Maximum | 10.5 V | Safety Current Maximum | 14mA |
Signal Type | NAMUR Input, Relay Output | Shipping weight | 1 Kg |
Brand Name | MTL | Model Number | MTL5516C |
Certification | HART | Place of Origin | UK/China |
High Light | mtl5516c Switch ,mtl5516c Proximity ,eaton mtl5516c |
MTL5516C MTL Instruments Switch/Proximity Detector Interface
The MTL5516/C enable two safe-area loads to be controlled by a switch
or proximity detector located in a hazardous-area. When selected, open
or short circuit conditions in the field wiring are detected by the linefault-detect (LFD) facility and also indicated on the top of the module.
Phase reversal for each channel is selected by a switch on the side of
the module and output is provided by changeover relay contacts.
circuit in either field circuit.
SPECIFICATION
See also common specification
• Number of channels
Two
• Location of switches
Zone 0, IIC, T6 hazardous area
Div. 1, Group A hazardous location
• Location of proximity detector
Zone 0, IIC, T4–6 hazardous area if suitably certified
Div. 1, Group A hazardous location
• Hazardous-area inputs
Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR)
• .Voltage applied to sensor
7 to 9V dc from 1kΩ ±10%
• Input/output characteristics
Normal phase
Outputs closed if input > 2.1mA (< 2kΩ in input circuit)
Outputs open if input < 1.2mA (> 10kΩ in input circuit)
Hysteresis: 200µA (650Ω) nominal
• Line fault detection (LFD) (when selected)
User-selectable via switches on the side of the unit. Line faults are indicated by an LED for each channel. The channel output relay is
de-energised if an input line fault is detected.
Open-circuit alarm on if Iin < 50µA
Open-circuit alarm off if Iin > 250µA
Short-circuit alarm on if Rin < 100Ω
Short-circuit alarm off if Rin > 360Ω
Note: Resistors must be fitted when using the LFD facility with a contact input
500Ω to 1kΩ in series with switch
20kΩ to 25kΩ in parallel with switch
• Safe-area output
Two single-pole relays with changeover contacts
Note: reactive loads must be adequately suppressed
• Relay characteristics
Response time: 10ms maximum
Contact rating(Safe Area):
250V ac, 2A, cosØ >0.7,
40V dc, 2A, resistive load
Contact rating(Zone 2):35V, 2A, 100VA.
• Maximum current consumption
35mA at 24V
11.Power dissipation within unit
0.84W at 24V
• LED indicators
Green: power indication
Yellow: two: channel status, on when output energised
Red: two: LFD indication, on when line fault detected
• Safety description (each channel)
Uo=10.5V Io=14mA Po=37mW Um = 253V rms or dc
Related Models:
HCU16 | MTL5521 | MTL4544 |
HCU3700 | MTL5522 | MTL4544D |
HM64RIB20-1.0 | MTL5531 | MTL4546Y |
HM64RIB20-1.5 | MTL5532 | MTL4549Y |
HMM64 | MTL5541 | MTL4573 |
HMRIB16-1.0 | MTL5541S | MTL4575 |
HMS64 | MTL5544 | MTL4646Y |
HTP-SC32 | MTL5544D | MTL4850 |
MTL4044D | MTL5546 | MTL4851 |
MTL4511 | MTL5546Y | MTL4852 |
MTL4516 | MTL5561 | MTL5018 |
MTL4516C | MTL5573 | MTL5032 |
MTL4521 | MTL5575 | MTL5042 |
MTL4541 | MTL5582B | MTL5044 |
MTL4541 | MTL7728+ | MTL5049 |
Frequently Asked Questions
Q:Are the Products Genuine OEM Units?
A: These items have been certified by Achievers Automation Limited to be genuine OEM Units obtained through OEM or independent third-party channels.
Company Details
Business Type:
Distributor/Wholesaler,Trading Company
Year Established:
2012
Total Annual:
3000000-5000000
Employee Number:
10~15
Ecer Certification:
Verified Supplier
Achievers Automtation Limited deals with a complete range of industrial automation components and instruments with more than 12 years’ experience, and always try best to provide quality goods and timely services to our valued customers from over 45 countries worldwide. Achievers serves the Oi... Achievers Automtation Limited deals with a complete range of industrial automation components and instruments with more than 12 years’ experience, and always try best to provide quality goods and timely services to our valued customers from over 45 countries worldwide. Achievers serves the Oi...